If you installed a USB, PCI, and/or PCMCIA device, the Plug and Play Hardware Detection dialog opens. The displayed ports function as configured. To run InstaCal, click on Start Programs Measurement Computing InstaCal. When configured as single-ended, only the lower 4 ports are displayed. The MCC DAQ can be configured in InstaCal to behave as either a single-ended or differential DAQ. Note that changing the digital port direction for one port applies to all 8 ports in that port's group. Our recommendation for this device is to set all digital channels to be either input or output, and avoid changing analog outputs quickly when possible. The Transform's AnalogIn ports are always updated as rapidly as possible. Run InstaCal and add your MCC device 6 Run InstaCal and add your MCC device To run InstaCal and add an MCC device to the InstaCal configuration, complete the following steps. It sets the rate at which the D to A outputs are updated, on average. USB-1408FS relies upon the Microsoft Human Interface Device (HID) class drivers. An instance of a server through which this channel is opened. Your new Measurement Computing product comes with a fantastic extra. Using a particular channel number here, will select which DAQ device to read / write to. Tick Period: The Tick Period property only affects the AnalogOut ports. Before an MC DAQ device can be used, one has to load it and assign a channel number to it using InstaCal. Enter the board number in the Transform's Selected Board Number property. the Measurement Computing PCI-DIO24 cards, they are cheap and their drivers. The board number assigned to the device in InstaCal is the number used to recognize the device in NI LabVIEW. InstaCal assigns a board number to each device it detects on the system. The USB-1616FS also provides one 32-bit counter and 8 digital I/O lines. Open InstaCal and configure the hardware. Description Measurement Computing's USB-1616FS is a USB-based device that provides 16 simultaneously sampled 16-bit analog inputs with sample rates up to 50 kS/s per channel, continuous module throughputs of 150 kS/s, and 32 kilosample bursts up to 200 kS/s. 1608FS is a composite device with multiple interfaces. DMDX can interface with other computers or equipment with the addition of a. Connect the MCC hardware that you want to use in NI LabVIEW. Run the InstaCal utility (from the Start menu). Thank you for purchasing the USB-1608FS from Measurement Computing.
#INSTACAL MEASUREMENT COMPUTING DEVICES DRIVER INSTALL#
Install the appropriate drivers for your device and the Measurement Computing InstaCal utility.Ģ. The MCC USB Device (DAQ) Transform connects MxVDev with a Measurement Computing USB-3105, USB-1208FS/LS, or SwitchAndSense.ġ.